ISO metric fits combine hole and shaft tolerance zones to create clearance, transition or interference. This table indexes common fit purposes and example code pairs without publishing size-specific tolerance deviations. Use the exact nominal size and current ISO 286 limits to calculate the real assembly condition.
Preferred ISO Metric Fits table
Preferred ISO metric fit purpose index
Qualitative guide to common clearance, transition and interference fit purposes.
1–5 of 5 matching rows (5 total)
Free engineering resource
Unlock CSV downloads and printing
Enter your email to download the displayed table page as CSV or print it.
CSV and print access for this browser session
Submit the form to unlock CSV downloads and printing.
Search and sort apply to all 5 rows. Print and CSV include only the 5 rows shown on this page.
Separate fit intent from limits
An ISO fit combines a hole tolerance zone and a shaft tolerance zone. The letter positions the zone relative to nominal size, and the grade sets its width. The same nominal diameter can yield different maximum clearance and minimum interference depending on the chosen pair. Use a tolerance calculation for the actual size instead of relying on the short code as if it were a fixed gap.
Choose movement and retention requirements
First decide whether the parts should run, slide, locate, or remain fixed. Consider lubrication, speed, load direction, temperature, contamination and maintenance. Clearance accommodates relative motion but may allow radial play; interference improves retention but can distort thin members or alter bearing clearance. A transition fit requires checking both possible outcomes at the tolerance extremes.
Account for manufacturing and inspection
A nominal fit is useful only if the process can produce and measure the required limits. Identify turning, grinding, boring, reaming, honing, coating or heat treatment steps that affect size and form. Select gauges and measurement methods that can resolve the tolerance. Confirm that the supplier understands the fit system and the drawing’s datum and inspection requirements.
Apply the reference carefully
After selecting an intent, calculate the limits for both features and combine them into maximum and minimum clearance or interference. Then check the assembled system: engagement length, material stiffness, surface finish, thermal growth, coating allowance, press force, service loads and disassembly needs. Fit selection can interact with bearing internal clearance, shaft deflection, alignment and seal operation. Record the ISO edition, nominal diameter, full code pair, units and assumptions with the design.
Examples are starting points only. Confirm the precise preferred series and size-specific deviations in current ISO 286 documentation and validate the joint for its real operating conditions.
Document the thread or fit specification
Record the complete designation, nominal size, selected class pair, units, source edition and the condition under which the measurement is made. A code by itself may leave out the mating feature or the required inspection method. If the part is coated, heat treated, lubricated, assembled hot or used at a different operating temperature, account for those conditions before selecting limits. Keep the drawing, supplier certificate and calculation consistent.
Check units and boundary rules
Distinguish nominal size from maximum and minimum limits, and distinguish a tolerance zone from the resulting clearance or interference. Confirm whether a stated interval is open or closed at either end. Convert millimetres, inches, micrometres and TPI carefully, retaining enough precision for the specified class. Do not round an intermediate value in a way that changes the acceptance boundary. If the source’s scope does not match the part, obtain a matching reference before proceeding.
Keep the decision reproducible
Save the selected inputs, calculation method, source date and reviewer with the design record. Another engineer or inspector should be able to identify which feature limits were used and reproduce the fit or thread check. Revisit the selection when the size, material, supplier, coating, process or standard revision changes. A compact reference table helps with early comparison; production approval still depends on the exact drawing and current governing requirements. Verify any value used in a production release against the present standard, not only a cached chart or a prior project file. When two features are manufactured separately, the final condition comes from both measured limits; check the worst-case pair and document any inspection or sorting assumption. Supplier-specific advice applies only to the named product and process. Keep the rationale with the approved drawing.
Source
Mitsubishi Materials, ISO fit tolerance table. Accessed October 18, 2026.