Home » Stick Welding Electrode Characteristics

A stick electrode’s diameter and classification help narrow a starting current, but the welder and the joint still matter. This table transcribes selected steel settings from the Lincoln Electric SPRINTER 180Si operator manual. It compares two electrode groups across three diameters and three plate-thickness bands, preserving the manual’s 230 V input marker.

Stick Welding Electrode Characteristics table

MECHANITEC / ENGINEERING REFERENCE

Stick welding electrode amperage examples by diameter and plate thickness

Lincoln Electric SPRINTER 180Si manual current recommendations for selected steel electrode families and plate thicknesses.

1–18 of 18 matching rows (18 total)

Stick welding electrode amperage examples by diameter and plate thickness — page 1 of 1
Electrode family Material and polarity Electrode diameter Plate thickness Manual current range 230 V input required
E6010 / E6011 / E6013 Steel; DC+ 3/32 in (2.4 mm) 12 gauge (2.7 mm) 50–70 No
E6010 / E6011 / E6013 Steel; DC+ 3/32 in (2.4 mm) 10 gauge (3.4 mm) 60–80 No
E6010 / E6011 / E6013 Steel; DC+ 3/32 in (2.4 mm) 3/16 in (4.7 mm) — No
E6010 / E6011 / E6013 Steel; DC+ 1/8 in (3.2 mm) 12 gauge (2.7 mm) 65–85 No
E6010 / E6011 / E6013 Steel; DC+ 1/8 in (3.2 mm) 10 gauge (3.4 mm) 75–95 No
E6010 / E6011 / E6013 Steel; DC+ 1/8 in (3.2 mm) 3/16 in (4.7 mm) 90–110* Yes
E6010 / E6011 / E6013 Steel; DC+ 5/32 in (4.0 mm) 12 gauge (2.7 mm) 90–110* Yes
E6010 / E6011 / E6013 Steel; DC+ 5/32 in (4.0 mm) 10 gauge (3.4 mm) 115–135* Yes
E6010 / E6011 / E6013 Steel; DC+ 5/32 in (4.0 mm) 3/16 in (4.7 mm) 130–150* Yes
E7018 Steel; DC+ 3/32 in (2.4 mm) 12 gauge (2.7 mm) 70–90 No
E7018 Steel; DC+ 3/32 in (2.4 mm) 10 gauge (3.4 mm) 80–100 No
E7018 Steel; DC+ 3/32 in (2.4 mm) 3/16 in (4.7 mm) 90–110* Yes
E7018 Steel; DC+ 1/8 in (3.2 mm) 12 gauge (2.7 mm) 90–110* Yes
E7018 Steel; DC+ 1/8 in (3.2 mm) 10 gauge (3.4 mm) 105–125* Yes
E7018 Steel; DC+ 1/8 in (3.2 mm) 3/16 in (4.7 mm) 115–135* Yes
E7018 Steel; DC+ 5/32 in (4.0 mm) 12 gauge (2.7 mm) 105–125* Yes
E7018 Steel; DC+ 5/32 in (4.0 mm) 10 gauge (3.4 mm) 115–135* Yes
E7018 Steel; DC+ 5/32 in (4.0 mm) 3/16 in (4.7 mm) 140–160* Yes

Search and sort apply to all 18 rows. Print and CSV include only the 18 rows shown on this page.

How to read the current rows

The manual groups E6010, E6011, and E6013 at the same listed settings for this machine, and gives E7018 a separate set. The amperage range changes with rod diameter and steel thickness. An asterisk on an entry means that the manual calls for 230 V input. A dash means the chart provides no range for that combination. These are reference starting points from one power source, not universal electrode limits.

E6010, E6011, and E6013 are not interchangeable

Although the manual groups these classifications in one amperage section, their operating behavior differs. Lincoln describes E6010 and E6011 as deeper penetrating and suitable for all positions, with frequent use in pipe work. E6013 is described as shallower penetrating and useful for wide root openings or poor fit-up. The grouping should not be mistaken for identical chemistry, procedure qualification, or weld properties.

E7018 applications

The manual identifies E7018 as a low-hydrogen electrode for joints involving high-strength structural, high-carbon, or low-alloy steels. It describes a smooth arc with medium penetration and all-position use. Low-hydrogen electrodes also have handling and storage requirements that depend on the product specification. Check the electrode packaging and manufacturer instructions for exposure limits, rebaking rules, and permitted storage conditions.

The chart’s suggested current generally rises as the electrode diameter increases and as the plate thickness band becomes heavier. This is a practical trend, not a standalone rule for choosing the rod. For example, the chart lists 3/32-inch E6010/E6011/E6013 at 50–70 A for 12-gauge steel and 60–80 A for 10-gauge steel, while the 5/32-inch rod uses higher values and requires 230 V for the starred entries.

Choose the welding process conditions first

The table covers steel with DC positive for the listed stick settings. Confirm that the chosen electrode classification, polarity, and machine output agree with the product data sheet. Joint design, root gap, fit-up, position, pass sequence, base-metal chemistry, and heat input can change the preferred setting. A current chart cannot replace a qualified welding procedure specification where one is required.

Machine limits matter

The SPRINTER manual’s starred values explicitly require a 230 V input. A power source on another input voltage may not deliver the same output or duty cycle. The cable, electrode holder, work lead, input circuit, and thermal condition also affect safe operation. Use the manual for the specific machine connected to the work rather than copying a setting from a chart for a different model.

A starting range is not acceptance criteria

A current setting that produces an acceptable arc does not prove that the weld meets a code, strength, or inspection requirement. Qualification may specify electrode classification, diameter, polarity, current, voltage, travel speed, preheat, interpass temperature, position, and joint details. Keep the procedure and inspection requirements with the work order, particularly on pressure, structural, or safety-related welds.

Use with the electrode datasheet

The manual summarizes broad electrode family behavior, while individual manufacturers publish product-specific current windows, position limits, deposition behavior, and storage directions. Compare the exact brand and classification to its current datasheet. If two products share a classification, they may still differ in recommended current or handling. The table is useful for quick orientation but should not supersede those product-specific instructions.

Values and rounding

All current ranges are copied as whole amperes, and the inch/mm diameters and thicknesses follow the manual’s printed labels. The text field preserves the chart’s dash for a missing range; numeric lower and upper fields are set to zero only as a machine-readable placeholder for that unavailable cell. Do not interpret those zeros as permission to weld at zero current or as an actual operating recommendation.

Safety and ventilation

Welding creates electrical, fume, ultraviolet, heat, and fire hazards. Follow the equipment manual, electrode safety data, site controls, and applicable occupational requirements. Provide suitable ventilation and protective equipment, secure the work area, and inspect leads and connections. This quick table only concerns machine-recommended amperage values; it is not a general safety guide or a substitute for welder training.

Source

Lincoln Electric, SPRINTER 180Si Operator’s Manual. The table labels which values are sourced and which are calculated. Accessed October 18, 2026.