When a solid warms, its dimensions usually change. For a small temperature interval near a stated reference condition, the linear estimate is ΔL = αL₀ΔT, where α is the linear expansion coefficient, L₀ is the starting length, and ΔT is the temperature change. This reference uses NIST NCNR values reported for selected materials at 295 K and calculates the illustrative change for a 100 mm length over a 1 K rise.
Expansion coefficients and example change
Thermal expansion length change reference near 295 K
NIST-reported linear expansion coefficients for selected materials with an illustrative 100 mm length change for a 1 K rise.
1–8 of 8 matching rows (8 total)
Free engineering resource
Unlock CSV downloads and printing
Enter your email to download the displayed table page as CSV or print it.
CSV and print access for this browser session
Submit the form to unlock CSV downloads and printing.
Search and sort apply to all 8 rows. Print and CSV include only the 8 rows shown on this page.
How to read the calculation
The coefficient column is reported in millionths per kelvin. The example change is in micrometres. For instance, the listed aluminum value of 22.91 × 10⁻⁶/K gives about 2.291 μm for a 100 mm length and a 1 K increase. To estimate a different length or small temperature step near the same reference condition, scale the example in proportion to length and ΔT.
For a larger temperature interval, a constant coefficient may not represent the whole range. A more accurate estimate uses temperature-dependent data or an average coefficient explicitly defined over the interval. Materials can also expand differently by direction, especially when rolled, drawn, laminated, or otherwise anisotropic. Use the correct product form and orientation when fit or alignment depends on the result.
Conditions and material identity
The source labels the data as properties of selected materials at 295 K. It lists pure elements as well as stainless steel 304 and a brass composition of 70% copper and 30% zinc. Those alloy rows are not generic values for every stainless steel or brass product. Heat treatment, exact composition, processing, and measurement direction may matter in a detailed design.
The calculated example assumes uniform temperature change, free expansion, and a small interval around the tabulated condition. It does not include restraint, thermal gradients, joints, fasteners, creep, plastic deformation, phase changes, or stress caused by temperature mismatch. Do not use this short reference as a substitute for a material specification in a tight-tolerance, pressure, or safety-critical assembly.
Source
NIST Center for Neutron Research, Reference Tables reports linear thermal expansion coefficients for selected metals at 295 K. The example length changes are calculations from those coefficients using ΔL = αL₀ΔT.
Apply the local estimate
For a freely expanding bar, the change is proportional to the initial length and temperature step when the coefficient is treated as constant. A 500 mm piece with the listed aluminum coefficient would have an illustrative change five times the 100 mm row for the same 1 K step. A 10 K step would multiply the local estimate by ten, but that scaling is only a rough approximation because the coefficient can vary with temperature.
Design clearances often depend on the difference between two components rather than the growth of one part alone. If both parts heat together, compare their material coefficients and dimensions. If one part is insulated, heated locally, or connected to a cooler structure, a uniform-temperature assumption can be wrong. Fasteners and restraints can convert free expansion into stress or distortion.
Use this table to understand scale and direction, then select data for the actual grade, product form, temperature range, and orientation. For precision fits or long spans over broad temperatures, integrate or use the source’s temperature-dependent expansion data rather than multiplying one near-room-temperature coefficient across the entire interval.
Temperature difference has the same numeric value in kelvins and degrees Celsius, so ΔT = 1 K is also a one-degree Celsius change. Absolute reference temperature is different: 295 K is not the same number as 295 °C. Keep the coefficient basis and the change interval distinct when converting temperatures or building a calculation sheet. Check the unit labels in drawings and simulation software, since a mistaken scale or absolute temperature can overwhelm the small dimensional change being estimated.