Fluid properties only make sense when temperature, pressure, and phase are stated. This table compares six common substances using the NIST Chemistry WebBook at 20 °C and 14.6959 psia (approximately one standard atmosphere). NIST returns liquid water and vapor values for ammonia, nitrogen, carbon dioxide, propane, and methane at that condition. The reported phase is part of the result, not an optional label.
Density and transport properties
Common fluid properties at 20 °C and 1 atmosphere
Compare NIST-reported phase, density, dynamic viscosity, and thermal conductivity for six fluids at one stated condition.
1–6 of 6 matching rows (6 total)
Free engineering resource
Unlock CSV downloads and printing
Enter your email to download the displayed table page as CSV or print it.
CSV and print access for this browser session
Submit the form to unlock CSV downloads and printing.
Search and sort apply to all 6 rows. Print and CSV include only the 6 rows shown on this page.
Reading the comparison
Density describes mass per volume. Dynamic viscosity describes resistance to shear, while thermal conductivity describes heat transfer through the material. They are different properties and should not be used interchangeably. The table reports viscosity in micro pascal-seconds; divide by 1,000 to express the same value in millipascal-seconds. Density is in kilograms per cubic metre and thermal conductivity is in watts per metre-kelvin.
At the shared condition, water is a liquid while the selected gases are vapors. That difference explains much of the density gap, but it does not make one fluid “heavier” in every state. Raising pressure or changing temperature can change density substantially, and a substance near a saturation boundary may change phase. The NIST query result includes the calculated phase for its condition; do not carry that phase label to a different operating point.
Choosing a property source
Use the rows for comparisons at the stated condition or for checking a preliminary calculation. If a design requires a different pressure or temperature, query the corresponding fluid model at that exact state. Confirm that the model covers the desired range and composition. Commercial fuels, refrigerants, compressed gas mixtures, and process streams may contain additives or multiple components, so a pure-substance value may not represent the material in a system.
These values do not establish safe storage pressure, allowable temperature, chemical compatibility, flow capacity, or equipment ratings. For pressure equipment, consult the applicable code, supplier data, and process-safety requirements. For a mixture, use mixture-specific data rather than averaging pure-fluid rows. Near a phase boundary, verify both the state and the property basis before using a value.
Source
Each row links to its own NIST Chemistry WebBook, Standard Reference Database 69 query. NIST supplies thermophysical properties including density, viscosity, and thermal conductivity for the listed fluids.
Check state before using a value
A property lookup starts with the identity of the fluid and the operating state. Confirm the chemical species or mixture, the temperature scale, the pressure basis, and whether the pressure is absolute or gauge. This table uses absolute pressure in psia. Gauge pressure must be converted before comparing against these rows. A pressure reading of zero psig, for example, is approximately atmospheric pressure rather than vacuum.
For gas systems, a density suitable for a quick mass estimate can be very different from liquid density. For liquids, viscosity can shift noticeably with temperature even when density changes only slightly. Heat-transfer calculations also depend on the fluid state and may require additional properties such as heat capacity. NIST returns several properties for each query, but this compact page includes only the columns listed in the table.
If a process uses a blend, dissolved gas, contamination, or high purity specification, record that composition and use data for the actual fluid. Do not combine values from different temperatures or phases into one row. Keep a calculation trace showing the source query and conditions used so another engineer can repeat the lookup.
Use absolute units consistently in any follow-on calculation. The dataset rounds the pressure display to 14.696 psia while NIST evaluates the query at 14.6959 psia; this is a display rounding only. When close tolerances matter, retain the query conditions and source precision rather than treating the rounded display as an exact boundary.