Choosing MIG shielding gas requires the base metal and filler classification to be considered together with transfer mode and the qualified welding procedure. Lincoln Electric’s GMAW Shielding Gas Selection Guide lists example gas blends for selected electrode families. This table reorganizes a selection of those manufacturer recommendations by metal family; it does not claim every listed blend works for every wire, position, joint, or machine.
Selected Lincoln Electric GMAW shielding gas options
Selected shielding gas blends and process constraints from Lincoln Electric’s GMAW Shielding Gas Selection Guide.
1–10 of 10 matching rows (10 total)
Free engineering resource
Unlock CSV downloads and printing
Enter your email to download the displayed table page as CSV or print it.
CSV and print access for this browser session
Submit the form to unlock CSV downloads and printing.
Search and sort apply to all 10 rows. Print and CSV include only the 10 rows shown on this page.
Start with the filler and transfer process
Shielding-gas selection affects arc behavior, metal transfer, bead shape, penetration, spatter, and weld chemistry. The correct choice is therefore not simply “argon for aluminum” or “CO2 for steel.” Identify the exact electrode classification first, then check whether the procedure uses short-circuit, surface-tension-transfer (STT), axial spray, or pulsed GMAW. The manufacturer guide lists broad options and process notes, but does not always pair every gas blend with one exact transfer mode in a way that should be inferred from a compact summary table.
For example, the guide lists several argon/CO2 and argon/oxygen blends for selected carbon-steel electrodes. Its aluminum examples include ER1100, ER4043, ER4047, ER5183, ER5356, ER5554, and ER5556, with argon/helium options. Lincoln explicitly excludes GMAW short-circuit transfer for that aluminum group. Copper-nickel and copper-alloy entries also call for attention to transfer restrictions and filler type rather than being treated like a carbon-steel procedure.
Use the composition as written
Gas percentages in the table are volume fractions as stated by Lincoln. Keep the balance gas and each addition clear: for instance, 90% argon, 7.5% CO2, and 2.5% oxygen is a three-component mixture. Do not confuse a 2% oxygen addition with 2% carbon dioxide, or assume blends with similar argon content produce identical weld behavior. Small changes to active-gas content can alter the arc and transfer characteristics.
The table groups selected electrodes and alloy families but does not identify a single product brand or certify compatibility with every wire. Check the current wire data sheet for its recommended gases and operating windows. A gas blend may be unsuitable for the required mechanical properties, corrosion resistance, position, or code procedure even if it appears in a general selection guide.
Confirm the welding procedure
Before welding, verify electrode classification, base-metal specification, joint design, thickness, position, shielding gas, flow rate, polarity, contact-tip-to-work distance, travel speed, and preheat or interpass controls as applicable. Follow the approved WPS and governing welding code. A gas chart does not qualify a procedure or establish the required strength, toughness, corrosion performance, or defect acceptance.
Use the gas supplier’s label and certificate to confirm actual blend composition and cylinder identity. Check the regulator, flowmeter, hose, connections, and gas coverage at the work area. Excessive flow can create turbulence and entrain air; too little flow, leaks, drafts, or poor nozzle condition can also reduce shielding. Correct the cause of porosity or unstable transfer rather than changing gas blindly.
Keep the gas cylinder or bulk-supply identification with the procedure record. If a blend is changed, record its exact composition rather than only a trade name, since names can vary by supplier and region. Verify that the regulator, hose, connections, and flow measurement are suitable for the gas. In mechanized or robotic work, confirm actual shielding coverage at the torch under operating conditions instead of relying only on a static regulator reading.
Limits of a selection chart
The recommendations here are selected entries from Lincoln Electric’s guide, not an exhaustive catalog. They are especially not a universal WPS. A qualified welding engineer or procedure owner should review any change to shielding gas, filler, transfer process, or joint conditions on a code-controlled job. Where a wire manufacturer’s current data sheet or a qualified procedure is narrower than a general guide, follow the applicable controlled document.
Source: Lincoln Electric, GMAW Shielding Gas Selection Guide, page 15. The guide names base-metal groups, example electrodes, transfer methods, and candidate shielding-gas compositions. Confirm the latest product data and procedure requirements before use.
