Metric screw thread allowance describes the intentional clearance built into mating thread tolerance zones. Bossard’s reference lists selected standard coarse threads with external 6g limits and the corresponding common internal 6H class. This table presents only external screw major- and pitch-diameter limits for four sizes; it does not define the full mating tolerance or replace ISO 965.
Metric Screw Thread Allowances table
Metric screw thread allowance class reference
Selected ISO metric thread class examples and their mating-member roles.
1–4 of 4 matching rows (4 total)
Free engineering resource
Unlock CSV downloads and printing
Enter your email to download the displayed table page as CSV or print it.
CSV and print access for this browser session
Submit the form to unlock CSV downloads and printing.
Search and sort apply to all 4 rows. Print and CSV include only the 4 rows shown on this page.
Read the class pair
The first tolerance class in a mating-thread callout commonly applies to the internal thread and the second to the external thread, with letter case indicating the member. In the common 6H/6g combination, 6H identifies an internal tolerance zone and 6g an external zone. Always confirm the drawing’s notation convention and the governing standard before interpreting a callout.
Allowance and tolerance are different
Allowance is an intentional difference between mating parts at maximum material condition; tolerance is the permitted size variation for an individual feature. An external thread’s fundamental deviation can place its tolerance zone below the basic profile, providing clearance for assembly or coating. The complete mating fit depends on both internal and external limits, not a single allowance number.
Use only matching thread data
The table shows selected major- and pitch-diameter limits from a manufacturer reference for standard coarse metric external threads. Minor diameter has its own limits, and fine-pitch threads or alternate classes can differ. Pitch diameter is functionally important because it governs flank engagement, but it does not replace crest/root checks, lead, angle and gaging.
Apply the reference carefully
For design and procurement, specify the thread size and pitch, internal and external classes, engagement length, material, coating or plating condition, and inspection gage. Consider tapping process, form-tap versus cut-tap behavior, thread depth and the strength of the receiving material. Where a coated fastener is used, verify the allowance and coating rules before production. Check the current product catalog and standard for exact limits and ensure both mating members meet the same specification.
Values are selected examples from a manufacturer technical chart. Confirm them against current ISO 965 requirements and supplier documentation before manufacturing or acceptance.
Document the thread or fit specification
Record the complete designation, nominal size, selected class pair, units, source edition and the condition under which the measurement is made. A code by itself may leave out the mating feature or the required inspection method. If the part is coated, heat treated, lubricated, assembled hot or used at a different operating temperature, account for those conditions before selecting limits. Keep the drawing, supplier certificate and calculation consistent.
Check units and boundary rules
Distinguish nominal size from maximum and minimum limits, and distinguish a tolerance zone from the resulting clearance or interference. Confirm whether a stated interval is open or closed at either end. Convert millimetres, inches, micrometres and TPI carefully, retaining enough precision for the specified class. Do not round an intermediate value in a way that changes the acceptance boundary. If the source’s scope does not match the part, obtain a matching reference before proceeding.
Keep the decision reproducible
Save the selected inputs, calculation method, source date and reviewer with the design record. Another engineer or inspector should be able to identify which feature limits were used and reproduce the fit or thread check. Revisit the selection when the size, material, supplier, coating, process or standard revision changes. A compact reference table helps with early comparison; production approval still depends on the exact drawing and current governing requirements. Verify any value used in a production release against the present standard, not only a cached chart or a prior project file. When two features are manufactured separately, the final condition comes from both measured limits; check the worst-case pair and document any inspection or sorting assumption. Supplier-specific advice applies only to the named product and process. Keep the rationale with the approved drawing. Record the inspection result and any corrective action so later maintenance or redesign uses the same basis. If conditions change, repeat the fit assessment rather than carrying forward a value that no longer describes the assembly.
Source
Bossard, Metric ISO Threads. Accessed October 18, 2026.