A compression spring’s force must be specified at a defined length or deflection. This reference records a manufacturer-published ±10% load-at-length tolerance and separates it from a calculated worst-case illustration. Tolerances are not universal: the spring type, dimensions, test setup, operating point, and supplier agreement determine the acceptance range.
Compression Spring Load Tolerance Chart table
Compression spring load-at-length tolerance reference
Manufacturer reference tolerances for spring rate and compression load at a specified length.
1–2 of 2 matching rows (2 total)
Free engineering resource
Unlock CSV downloads and printing
Enter your email to download the displayed table page as CSV or print it.
CSV and print access for this browser session
Submit the form to unlock CSV downloads and printing.
Search and sort apply to all 2 rows. Print and CSV include only the 2 rows shown on this page.
Specify load at length
A spring load has meaning only when the spring is compressed to a stated length or deflection. A complete requirement identifies the measurement point, tolerance, orientation, conditioning, and test method. A free-length tolerance does not directly define the load tolerance. Specify the functional load point that matters to the assembly and confirm it with the supplier.
Manufacturer guidance in the table
Murphy & Read’s compression spring reference guide lists spring-rate tolerance of ±10% and load-at-length tolerance of ±10%. These are reference values from that manufacturer’s guide, not a universal requirement imposed on every spring. The published range can vary by design, quantity, material, manufacturing process, and negotiated inspection plan.
Rate tolerance and load tolerance
The guide lists these as separate characteristics. A rate check measures force change over a deflection interval; a load-at-length check measures force at a defined spring length. One does not automatically replace the other. If the assembly has a critical force requirement, specify the actual load at its functional length and agree on the inspection method.
Why rate and load differ
Spring rate is the change in force per unit deflection over a specified operating range. Load at a point also depends on free length, initial compression, and where the measurement occurs. A rate tolerance by itself is not enough to establish the allowed load at length. If the assembly is sensitive to force, specify and inspect the force directly.
Test conditions matter
Temperature, seating, end squareness, platen alignment, and loading direction can affect a measured value. A consistent test uses parallel plates, controlled movement, and the same measurement point for every part. Record conditioning and whether the measurement is taken on loading or unloading when hysteresis or friction is relevant. Agree these details before receiving a production lot.
Tolerance and functional design
A design should tolerate the full permitted load range across manufacturing and service. Check minimum force for contact or return functions and maximum force for component stress, actuator capacity, and assembly loads. If the allowed range is too wide, discuss tighter tolerance feasibility and inspection cost with the spring manufacturer before releasing the drawing.
Avoid false precision
A percentage on paper does not guarantee that every spring will land at the nominal value. Confirm how the supplier samples, measures, sorts, and reports a lot. Ask whether the tolerance applies to each spring or a population average. Keep the units, load point, and acceptance limits clear; do not combine nominal rate and free-length limits as if they were an independent load guarantee.
Use the chart as a starting point
The reference helps frame a supplier discussion. It is not a replacement for the current design reference or a signed purchase specification. For safety-critical or tightly controlled assemblies, require a defined test plan, traceability, and review by a qualified spring engineer. Update the requirement if material, geometry, coating, or operating temperature changes.
Applying the reference
Before using a row, confirm its units, assumptions, source edition, and fit with the actual project. These values support preliminary learning and comparison; they do not replace an approved drawing, current product data, or qualified review of the geometry, material, and operating conditions. Keep the selected inputs and method with the design record so another engineer can reproduce the result and identify when a different model applies. Recheck the source when specifications or product documentation change.
Source
Murphy & Read Spring, Compression Springs Design Reference. The table identifies sourced and calculated values. Accessed October 18, 2026.