A shrink-fit assembly temporarily changes component size so an interference fit can be assembled without forcing the parts together. This reference calculates the temperature difference required to grow selected steel bores by an assumed interference plus a small assembly gap. The inputs are illustrative; they are not recommended fit allowances, tolerances, or bearing installation settings.
Force and Shrink Fit Allowances table
Illustrative shrink-fit thermal assembly allowances
Calculated thermal expansion required to clear assumed interference and temporary assembly allowance for selected steel bearing bores.
1–3 of 3 matching rows (3 total)
Free engineering resource
Unlock CSV downloads and printing
Enter your email to download the displayed table page as CSV or print it.
CSV and print access for this browser session
Submit the form to unlock CSV downloads and printing.
Search and sort apply to all 3 rows. Print and CSV include only the 3 rows shown on this page.
Thermal growth relation
For a uniform temperature change, the simple linear estimate is ΔD = αDΔT. Here D is the starting bore diameter, α is the linear thermal expansion coefficient, and ΔT is the temperature change. Rearranging gives ΔT = ΔD/(αD). The calculation approximates free expansion and does not model contact pressure, restraint, temperature gradients, or a real bearing’s dimensional response.
What the rows assume
The table uses representative bore diameters of 25, 50, and 100 mm. It assigns a diametral interference for each example and adds an assumed 0.02 mm temporary assembly clearance. The resulting required diameter growth is divided by an assumed 12×10⁻⁶/°C coefficient for steel. NASA reports that coefficient for 4340 steel; it should not be transferred automatically to every bearing alloy or component.
Compare with SKF guidance carefully
SKF says a bearing temperature about 65°C above the shaft is normally sufficient for mounting, and warns against exceeding its temperature limits. That is practical manufacturer guidance, not a universal calculation result. The temperature difference needed for one geometric example may not match a real bearing because fit tolerance, thermal distribution, handling time, and component stiffness all matter.
Force fitting is a different method
A press fit applies mechanical force while the components remain near the same temperature. Required force depends on contact pressure, interface geometry, length, surface condition, lubrication, and elastic or plastic behavior. The thermal-growth equation does not calculate that force. Follow the bearing manufacturer’s mounting method so assembly force passes through the correct ring rather than rolling elements.
Allowance is not interference selection
An engineer first selects the fit based on load direction, magnitude, shock, rotation, material, and operating temperature. A chosen fit produces a tolerance range; the actual parts can land anywhere within it. The assumed interference in this table exists only to illustrate thermal clearance. It is not a substitute for an ISO or manufacturer fit calculation for a specific assembly.
Temperature limits matter
Heating changes more than bore size. Excessive temperature can affect heat treatment, seals, grease, dimensional stability, and hardness. SKF gives specific maximum temperatures for its bearings and a lower maximum for sealed or shielded units. Verify the exact product’s instructions before mounting. A general coefficient cannot establish a safe heating target or prevent damage.
Other sources of uncertainty
Actual bore, shaft diameter, roundness, surface finish, and measurement temperature affect clearance. Both parts may be warm or cool, so use the relative temperature and the expansion behavior of each material. If a housing or shaft has a different coefficient, differential expansion changes the fit. The simple examples assume the inner member remains at its starting dimension.
A safe calculation workflow
Identify the exact bearing and fit, obtain the current dimensional limits, and calculate minimum and maximum interference. Choose a manufacturer-approved mounting method and permissible temperature. If you estimate thermal expansion, state the material coefficient, reference size, required gap, and temperature difference. Verify the procedure with the bearing supplier before using it on a production or safety-critical assembly.
Applying the reference
Before using a row, confirm its units, assumptions, source edition, and fit with the actual project. These values support preliminary learning and comparison; they do not replace an approved drawing, current product data, or qualified review of the geometry, material, and operating conditions. Keep the selected inputs and method with the design record so another engineer can reproduce the result and identify when a different model applies. Recheck the source when specifications or product documentation change.
Source
SKF, Bearing Maintenance Handbook, Hot Mounting. The table identifies sourced and calculated values. Accessed October 18, 2026.