A shaft can experience bending and torque at the same time, and a transient load can raise the design demand above a steady operating value. RoyMech publishes indicative shock and fatigue factors for bending moments and transmitted torque. This reference preserves the ranges and names the load cases so the factors are not mistaken for material properties or a complete shaft design.
Shaft Shock and Fatigue Design Factors table
Indicative shaft shock and fatigue factors
RoyMech factor ranges for three load descriptions; not a shaft sizing table.
1–3 of 3 matching rows (3 total)
Free engineering resource
Unlock CSV downloads and printing
Enter your email to download the displayed table page as CSV or print it.
CSV and print access for this browser session
Submit the form to unlock CSV downloads and printing.
Search and sort apply to all 3 rows. Print and CSV include only the 3 rows shown on this page.
Read the two factors separately
RoyMech labels the bending-moment multiplier K_m and the torque multiplier K_t. The factors are not interchangeable: bending moment and torque enter the stress calculation differently. Apply the method’s definitions and equations consistently, with each applied to the corresponding load component. A factor is a multiplier, not a stress value or a safety factor by itself.
Select a load description from evidence
“Steady,” “minor shock,” and “heavy shock” are qualitative descriptions. Translate machine behavior into a defensible case using start-up, stop, impact, jam, cyclic operation, and load-reversal information. If the event spectrum is unknown, gather operating data or use a justified conservative case and document it. Do not choose a lower row simply because it makes the shaft smaller.
Ranges are not confidence intervals
The ranges reflect engineering judgment in the cited reference, not a statistical distribution or guaranteed boundary for every machine. A chosen point within a range should be justified by the actual service conditions and design method. If transient loads are measured or calculated directly, avoid counting the same amplification twice by also applying a shock factor without checking the method.
Use the reference in context
A complete shaft check starts with a free-body diagram, resolves loads in both transverse planes, combines bending moments, and maps torque along the shaft. It then evaluates the critical section, stress concentrations at shoulders and keyways, combined failure criteria, fatigue strength, and radial or angular deflection. Bearings, gears, couplings, keys, and splines impose geometry and alignment limits that may control before material strength. The table helps identify an input, not the final diameter.
Use current material certificates, geometry, load histories, and an accepted design method. Consider the rotating shaft’s fatigue cycle and critical speed where relevant. A qualified engineer should review machinery whose failure can harm people or damage critical equipment.
Define the design inputs
Before using a reference value, write down the part or operating condition it represents, the units, the measurement location, and the applicable material or configuration. A row only has meaning inside those boundaries. If the drawing, supplier record, or actual equipment differs from an assumption shown here, stop and obtain a matching source or calculate the case using a method appropriate to the real geometry. Do not silently substitute a nearby row because its number appears conservative.
Check units and limits
Confirm whether each value is a nominal value, limit, range, factor, or calculated example. Keep conversion and rounding steps visible, especially where a small unit error can materially change the result. Check whether a stated boundary is inclusive and whether the source applies to the size, process, temperature, grade, or edition in question. Avoid extrapolating past a published range unless the source explicitly defines a valid formula for doing so.
Keep the result reproducible
For an engineering decision, retain the source edition, selected inputs, calculation method, intermediate values, and review date with the design record. A second person should be able to follow the same path and understand where the result came from. Recheck a supplier catalog or standard when the product changes, a new revision is issued, or an unexpected measurement appears. A reference table is most useful when it makes its scope clear and makes unsupported assumptions easy to spot.
Source
RoyMech, Shaft Design Basics. The table separates published values from calculations and identifies the conditions that define each row. Accessed October 18, 2026.