A face-seal gland is sized from the O-ring cross section and the sealing conditions. Parker’s inch-series chart separates groove-width guidance for liquids from the narrower vacuum and gas values, while listing gland depth, squeeze and corner radius for each size group. The dimensions below are a selected transcription of Design Chart 4-3; keep the size band and application with every lookup.
Inch O-Ring Gland Dimensions
Parker inch-series static face-seal gland dimensions
Selected inch-series O-ring cross sections and face-seal gland dimensions from Parker Design Chart 4-3.
1–7 of 7 matching rows (7 total)
Free engineering resource
Unlock CSV downloads and printing
Enter your email to download the displayed table page as CSV or print it.
CSV and print access for this browser session
Submit the form to unlock CSV downloads and printing.
Search and sort apply to all 7 rows. Print and CSV include only the 7 rows shown on this page.
The chart groups several AS568 dash numbers under each cross section. For example, the .070-inch actual cross section covers dash sizes 004 through 050, while the .103-inch section covers 102 through 178. The special 3/8-inch and 1/2-inch cross sections are listed separately. Use the row that matches the actual O-ring section rather than rounding to the nearest nominal fraction.
At a .139-inch cross section, Parker lists a gland depth from .101 to .107 inch and squeeze from .028 to .042 inch, corresponding to 20 to 30 percent. The groove width is .177 to .187 inch for liquids and .158 to .164 inch for vacuum and gases. Those different width ranges are intentional; do not substitute one for the other without checking the sealing application.
The nominal cross-section label and the actual size tolerance are separate entries. A .210-inch cross section is shown as .210 ±.005 inch. The listed gland depth and squeeze values define the chart’s design window, but the finished assembly also depends on the groove diameter, mating clearance, compound, pressure direction and temperature. The table does not determine those details for a specific seal.
Parker’s chart says these dimensions are intended primarily for face-type O-ring seals and low-temperature applications. It also describes a different groove diameter reference for internal and external pressure. When internal pressure acts outward, the groove is dimensioned by outside diameter; external pressure uses inside diameter. Follow the handbook diagram and current product data for the exact geometry.
A common mistake is to copy the groove width from a liquid application into a vacuum or gas gland. Another is to use these static face-seal values for a reciprocating rod or piston, where friction, lubrication, extrusion and motion change the design. The chart does not provide dynamic-seal dimensions, compound compatibility, pressure rating or surface finish for every fluid.
For inspection, record the dash size, measured cross section, pressure direction and specified groove dimensions. Check depth and width with suitable equipment, including corner radius and surface condition where they affect sealing. If a selected O-ring falls outside the listed groups or the service is outside the chart scope, consult the current Parker handbook or the seal supplier instead of interpolating.
Treat the table as a quick lookup, not a complete seal design. Confirm that the selected elastomer suits the fluid and temperature, and evaluate extrusion clearance at the actual pressure. The final gland should follow the controlled drawing and applicable engineering standard for the assembly.
A dimensional check should distinguish the free O-ring cross section from the compressed installed condition. The groove-depth range controls squeeze only when the mating face and gland geometry are also correct. Burrs, sharp corners, damaged finishes or a tilted joint can create a leak path even when a nominal depth falls inside the table range. Inspect the actual machined feature and its mating surface as part of the assembly review.
The handbook includes additional design charts for other static glands, dovetails and vacuum seals. Those charts have different geometries and assumptions. If the joint uses a captured groove, an unusual pressure direction or elevated temperature, find the matching design section instead of adapting the face-seal row. Confirm any change with the seal manufacturer and document the selected compound and dimensions.
Sources
Values are summarized from Parker’s O-Ring Handbook, Design Chart 4-3, which lists face-seal gland dimensions and pressure-direction notes.