Home » ANSI Locational Transition Fit Classes

A locational transition fit is used when assembled parts need accurate location and the resulting fit may be a small clearance or a small interference. The LT class designation is only one part of the specification: nominal size and the paired hole and shaft limits determine the actual assembly. This index lists the LT family without reproducing standard tolerance tables.

ANSI Locational Transition Fit Classes table

MECHANITEC / ENGINEERING REFERENCE

ANSI locational transition fit class index

Qualitative index of LT1–LT6 classes; no standard tolerance numbers reproduced.

1–6 of 6 matching rows (6 total)

ANSI locational transition fit class index — page 1 of 1
ANSI fit class Fit family General behavior Design intent
LT1 Locational transition May produce small clearance or small interference depending on actual mating sizes. Accurate location of assembled parts; verify the selected standard limits and assembly force.
LT2 Locational transition May produce small clearance or small interference depending on actual mating sizes. Accurate location of assembled parts; verify the selected standard limits and assembly force.
LT3 Locational transition May produce small clearance or small interference depending on actual mating sizes. Accurate location of assembled parts; verify the selected standard limits and assembly force.
LT4 Locational transition May produce small clearance or small interference depending on actual mating sizes. Accurate location of assembled parts; verify the selected standard limits and assembly force.
LT5 Locational transition May produce small clearance or small interference depending on actual mating sizes. Accurate location of assembled parts; verify the selected standard limits and assembly force.
LT6 Locational transition May produce small clearance or small interference depending on actual mating sizes. Accurate location of assembled parts; verify the selected standard limits and assembly force.

Search and sort apply to all 6 rows. Print and CSV include only the 6 rows shown on this page.

What transition means

A transition fit lies between clearance-fit and interference-fit outcomes. Depending on the realized sizes within the tolerance zones, a particular pair may assemble with slight clearance or require a light press. That variability is part of the class definition, so designers should evaluate both limit combinations rather than design only around the nominal dimensions.

Class labels need the size limits

The LT1–LT6 label does not tell a machinist the finished limit dimensions by itself. The governing fit standard defines deviations as a function of nominal size and the selected class. The historical reference linked here identifies the class names, but production drawings must use a current applicable edition and the exact limits needed for that nominal diameter.

Plan assembly and inspection

If hand assembly is required, estimate the worst-case interference and assembly force. If a press is expected, define the press method and protect thin walls, coatings and nearby features. Establish inspection gages and a measurement method that can distinguish the tolerance boundaries. A transition fit does not automatically provide a specified torque capacity or a guaranteed retention force.

Apply the reference carefully

Use the class index to frame a fit discussion, then specify hole and shaft limits, material pair, surface finish, length of engagement, temperature range and assembly process. Consider thermal expansion, coatings, lubricant, vibration and service loads. Confirm functional location with the complete stack-up, not a nominal-size comparison. If the location is critical, evaluate the tolerance stack, datum scheme and repeatability of the inspection method. Do not rely on class names alone when a drawing or supplier quote controls acceptance.

The linked ANSI table is a historical reference. Verify limits and class status against the current standard and project requirements before designing, machining or accepting a fit.

Define the design inputs

Before using a reference value, write down the part or operating condition it represents, the units, the measurement location, and the applicable material or configuration. A row only has meaning inside those boundaries. If the drawing, supplier record, or actual equipment differs from an assumption shown here, stop and obtain a matching source or calculate the case using a method appropriate to the real geometry. Do not silently substitute a nearby row because its number appears conservative.

Check units and limits

Confirm whether each value is a nominal value, limit, range, factor, or calculated example. Keep conversion and rounding steps visible, especially where a small unit error can materially change the result. Check whether a stated boundary is inclusive and whether the source applies to the size, process, temperature, grade, or edition in question. Avoid extrapolating past a published range unless the source explicitly defines a valid formula for doing so.

Keep the result reproducible

For an engineering decision, retain the source edition, selected inputs, calculation method, intermediate values, and review date with the design record. A second person should be able to follow the same path and understand where the result came from. Recheck a supplier catalog or standard when the product changes, a new revision is issued, or an unexpected measurement appears. A reference table is most useful when it makes its scope clear and makes unsupported assumptions easy to spot.

Source

ANSI B4.1-1967 (R1987), Transition Locational Fits (archived table reference). The dataset states whether each row is sourced or calculated and identifies the conditions that define it. Accessed October 18, 2026.